How to address jumping pipes without causing further damage.
Several
years ago, this author published an article titled “How Not to Use a Rubber
Expansion Joint.” The article addressed common installation and application
issues, but it did not discuss water hammer. That subject deserves a separate
article due to the unique circumstances and extreme effects, which can exceed
the design criteria of the system and individual components, including the
expansion joints.
Once
or twice each year I speak with a distressed engineer, and it is usually after
a system startup. The conversations are very similar:
Engineer: When a pump starts (or stops, or a valve opens or
closes), the pipes jump off the supports. It sounds like something is going to
explode in the piping. I want to add an expansion joint to absorb the shock.
Author: Although I like solving problems and selling expansion
joints, that would be a really bad idea.
Engineer: %@$#&!
This
is an understandable reaction, because the problem manifests itself at the
worst possible time. The construction team must turn the building over to the
owner. Maybe the project is behind schedule. All construction and design issues
have been resolved, the equipment is powered up, the switch is flipped and
suddenly there is another problem and potential delay.
Adding
an expansion joint to fix a hammering system is usually not a good idea,
although it can help in some circumstances.
Transient Events: Water Hammer
Water
hammer is one of four types of transients, or short-duration dynamic events,
that can result in extensive damage to a piping system. The four types of
transients are:
1.
Liquid
2.
Liquid and vapor
3.
Liquid and gas
4.
Gas
Elastomeric
joints are almost exclusively installed in liquid systems, most often with
water as the medium, so the focus of this article will be on water hammer.
Water
hammer is an event caused by a sudden change of velocity of a moving column of
water, resulting in a large pressure spike that travels through the pipe at a
high velocity. Common causes can be a hard start or stop of a pump or a fast
valve closure. The terms “sudden” and “fast” are relative, depending on the
event duration and the total length of affected pipe.
For
a demonstration of how high the pressures can rise, consider a simple
arrangement of a reservoir, long pipe and valve. The valve is normally open,
allowing water to flow from the reservoir through the valve and on to the
downstream equipment.
If
the valve closes quickly, the flowing water will stop suddenly. The sudden
deceleration down to zero velocity comes with a price, which is a large
pressure wave starting at the valve. This pressure wave propagates opposite the
direction of flow back to the reservoir. The wave moves at the speed of sound
of the fluid and pipe, which will be about 4,300 feet per second (ft/s) for
water in a steel pipe.
That
is not the end of the story. Once the wave reaches the end point (the
reservoir), it will reflect through the pipe. The reflected pressure wave is
now about the same magnitude, except it is below the static pressure in the
system. This continues within the system until friction and pipe wall
elasticity dampen the pressure spike energy.
If
the valve has a near-instantaneous closure, the magnitude of the pressure spike
can be estiated using the Joukowsky equation:
If the “expansion joint as shock absorber” idea is not
recommended, what options are available? The good news is that most systems can
be modified to eliminate water hammer. The bad news is that the system will
have to be modified. There likely will not be a cheap way out of the problem.
Typical sources of water hammer for heating, ventilation and air conditioning
(HVAC) or plumbing systems are:
·
Fast-closing valves (e.g., solenoid valves) or incorrect check
valve selections
·
Hard-start pumps (pumps that are either on or off, no
modulating)
Fast-closing
valves may be replaced with slower-acting valves. For example, a solenoid valve
may be replaced with a slower-acting ball or butterfly valve. If the problem is
with a check valve, several manufacturers offer models that reduce water hammer
risk at a pump discharge. A soft-start or variable frequency drive may be added
to a motor to modulate the start and stop. If these modifications are not
possible, another common solution is to add an accumulator near the source of
the water hammer. In this example, the accumulator can be added in the vicinity
of the valve.
Surge
If
the event is not as sudden or near-instantaneous, there is good news. There
will still be an increase in pressure, but it will not be as extreme. This is
known as surge. The resulting pressure increase should still be assessed, but
the potential for damage is less than with a hammer condition. If we use our
previous example but with a valve closing time of five seconds, the surge
calculation will be much different:
If the flow is 10 ft/s, the surge pressure will be 0.67
psi.
The difference between surge and hammer is the duration
of the event compared to the propagation time of the pressure wave through the
piping system, defined as:
·
t = 2L/a
·
L = distance from point of disturbance to end of
pipeline
·
a = speed of sound in full pipe
Until this point, the length of pipe was not a factor
in the determination of the pressure increase, but pipe length is now necessary
to determine the difference between hammer and surge. If the pipe length in the
previous example is 500 feet from valve to reservoir, the limiting event time
will be 0.23 seconds. Any event lasting approximately 0.23 seconds or less
would have the potential for water hammer. Events lasting much longer than 0.23
seconds will likely result in a surge event. A large, direct-acting solenoid
valve can change state in 20 to 40 milliseconds (.02 to .04 seconds). This type
of valve would not be a good choice for the system, and a slower-acting valve
would be better. Similarly, a motor start/stop event lasting 0.23 seconds or
less has the same potential for water hammer.
If the issue is with a check valve, the action should
actually be fast-closing. A fast-closing check valve prevents the flow from
accelerating in the opposite direction before the valve closes. Specifically,
check valves should have the following characteristics to reduce the risk of
water hammer:
·
The mass of the moving elements should be low.
·
The moving elements should not have far to
travel from being fully open to shut.
·
Springs are needed to initiate and assist
closure.
Piping systems are designed to be static. If the pipes
jump, people will pay attention and look for a quick solution. If the system is
experiencing water hammer, an elastomeric joint will not address the source of
the disturbance and may sustain damage due to the extreme pressure. Another
solution is required to address hammering. By contrast, surge events are longer
in duration and result in much less dramatic pressure increases. Elastomeric
joints are more compatible with surge conditions and can provide isolation
between the source and the connected piping.
To mitigate issues such as jumping
pipes without causing further damage, it's essential to ensure that the piping
system connected to an ANSI pump is properly designed and
installed. According to best practices, providing at least ten diameters of
straight pipe to the pump's suction inlet can help maintain optimal flow
conditions and reduce turbulence, which in turn minimizes mechanical stress on
the piping and pump components. Additionally, using highly rigid baseplates,
such as reinforced stilt or grout-installed designs, can enhance the stability
of the pump installation, further preventing undesirable movements and
potential damage.
It's also crucial to address piping
forces exerted on the ANSI pump
connections. Excessive pipe strain can lead to misalignment, increased
vibration, and premature wear of pump components. While ANSI standards provide
guidelines for acceptable piping loads, it's advisable to minimize these forces
as much as possible. Implementing flexible connectors or expansion joints can
accommodate thermal expansion and contraction, thereby reducing stress on the
pump nozzles. However, these solutions should be carefully engineered to avoid
introducing additional issues, such as pressure imbalances or mechanical
instability.